1. |
Work Space |
: 0.5 X 0.5 X 0.5 Mt to 1 X 1 X 1 Mt |
| |
|
|
2. |
Temp Range |
: + 10 to 100 Deg. C |
| |
|
|
3. |
Temp. Tolerance |
: +/- 1 Deg. C |
| |
|
|
4. |
Temp. Control |
: By Digital Temp. Controller for Dry & Wet Build |
| |
|
|
5. |
Temp. Sensor |
: PT 100 |
| |
|
|
6. |
Humidity |
: 95 +/- 3 % temp. Range 25 to 60 Deg. C |
| |
|
|
7. |
Power |
: 230 / 440 VAC |
| |
|
|
Optional Features:
|
1. |
PID controller |
| |
|
2. |
Inspector window with Two Pane Glass, Heater & Lamp. |
| |
|
3. |
Port holes of 25 mm dia for specimen wiring. |
| |
|
4. |
Chamber On delay timer. |
| |
|
5. |
Specimen trays. |
| |
|
6. |
Electrical terminals through wall |
|
|
| |
Systems Provided |
| |
|
| |
• Air-Circulation system
| |
1/20 Hp capacity continuous rated 230 Volts, single phase AC operated motor along with 12" dia fan has been provided for uniform temperature and humidity condition inside the chamber. |
• Heating system
| |
Low surface loading inconel tube heaters having capacity 500 watts-2nos. Has been provided to add heat inside the chamber. All the heaters are mounted in the conditioning space and will operate in the black zone. |
• Humidity system
| |
Low pressure moisture generator tank has been provided to generate the moisture and add humidity in the chamber. 2 KW capacity immersion heater having 1 V4 BSP threading has been provided inside the moisture generator tank. The moisture
generator tank has been provided along with low water level controller with
mechanical float type refilling arrangement . |
• Control panel and wiring
| |
Separate control panel provided on the top of the chamber which incorporate all the indicating and monitoring instruments with control switches, MCB'S , contactors, indicating lamps etc. All the wiring will be done as per IS color code with channel type wiring. |
• Utilities provided
| |
a. Chamber drain
b. Viewing window 30 x 30 cms 2 pane glass with low wattage heater
and manually operated wiper
c. Chamber interior light
d. Port hole 25 mm dia 1 no
e. Terminal panel - 6 nos 5 amp capacity
f. 30 Lts capacity S/S tank provided on the top for water storage |
• Safety protections provided
| |
a. MCB's for heaters
b. Over temperature safety cut-off with audio visual alarm.
c. Low water level indication with audio visual alarm |
• Water requirement
| |
30 Lts/day dematerialized water during the humidity test . |
Available in customized work-space sizes |
|
|
| |
|
|
|
S. No. 16/6, Nanded Phata, Near Savali Dhaba, Pune Sinhagad Road, Pune - 411041
Tel. No. : +91-20-24391267, 24211550, Email : refricon@refriconsystems.com
|
|